End-of-life detection of discharge electrodes by taking current-voltage characteristics of a fluorescent lamp

Authors

  • Motoi Wada Graduate School of Science and Engineering, Doshisha University Kyotanabe, Kyoto
  • Shigeo Gotoh Panasonic Electric Works Co., Ltd, Kadoma, Osaka
  • Shoji Inoue Graduate School of Science and Engineering, Doshisha University Kyotanabe, Kyoto
  • Toshiro Kasuya Graduate School of Science and Engineering, Doshisha University Kyotanabe, Kyoto
  • Takahiro Kenmotsu Faculty of Life and Medical Science, Doshisha University, Kyotanabe, Kyoto

Abstract

Current-voltage characteristics of a fluorescent lamp slowly change in accordance with the degradation of the electrodes. In the operation with a high frequency electronic ballast for a fluorescent lamp, change of electric current running through the electrode causes a sudden decrease in thermionic electron emission from the electrode working as a discharge cathode. This characteristic appears in one direction of current flow as the lamp is operated for a long time corresponding to the loss of oxide coatings from the electrode. Methods to distinguish degradation of electrodes of a fluorescent lamp are discussed.

Downloads

Issue

Article ID

SPP-2010-1C-02

Section

Materials Physics

Published

2010-10-25

How to Cite

[1]
M Wada, S Gotoh, S Inoue, T Kasuya, and T Kenmotsu, End-of-life detection of discharge electrodes by taking current-voltage characteristics of a fluorescent lamp, Proceedings of the Samahang Pisika ng Pilipinas 28, SPP-2010-1C-02 (2010). URL: https://proceedings.spp-online.org/article/view/SPP-2010-1C-02.